Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 31, 2017, 10:34 AM
  • J 0163_J 0162 _01312017_024037.mp4

Date
01/31/2017
W/O
619081
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00055
PipeID
P11405
Time
2:34 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4098
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
SAN PEDRO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_619081_TV05161_FEB2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
J 0163
Downstream MH
J 0162
Dir. of Survey
Downstream
Length Surveyed
50.7 ft.
Total Length
50.7 ft.
Structural Index
3
Structural Quick
3800
Structural Rating
24
O&M Index
2
O&M Quick
2811
O&M Rating
17
Overall Index
2
Overall Quick
Overall Rating
41
Pipe schematic from manhole J 0163 to J 0162
MH: J 0163MH: J 0162downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 01630 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area6.9 ft. MGO - General Observation - MAGNESIUM H.O. START6.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start35.7 ft. LR - Alignment Right, 10 %47 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish47.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish47.1 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH50.7 ft. AMH - Downstream Manhole, Survey Ends - J 0162

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    6.9 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0AMHJ 0163
47.1SAV
47DAGS
35.7LR
0MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
50.7AMHJ 0162
0MWM
47.1MGOMAGNEZIUM H.O. FINISH
6.9MGOMAGNESIUM H.O. START
6.9DAGS
6.9SAV
0MWL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2017-01-31T02:34:38-08:00
documentation
PRO PIPE
is_lateral_inspection
false