- Date
- 02/01/2017
- W/O
- 619081
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00055
- PipeID
- P11395
- Time
- 1:28 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4100
- Sewer Name
- J JOINT OUTFALL J - UNIT 1C
- City
- RANCHO PALOS VERDES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 40
- Purpose
- Routine Assessment
- Project
- WO_619081_TV05161_FEB2017
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- J 0155
- Downstream MH
- J 0154
- Dir. of Survey
- Downstream
- Length Surveyed
- 477.6 ft.
- Total Length
- 477.6 ft.
- Structural Index
- 3
- Structural Quick
- 3R00
- Structural Rating
- 282
- O&M Index
- 2
- O&M Quick
- 2R11
- O&M Rating
- 189
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 471
Pipe schematic from manhole J 0155 to J 0154 Observation photos (3)

2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

362.6 ft. - General Photograph