Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2017, 08:42 AM
  • J 0188_J 0187 _01262017_010757.mp4

Date
01/26/2017
W/O
619081
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00055
PipeID
P11427
Time
12:42 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4094
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
SAN PEDRO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47A
Purpose
Routine Assessment
Project
WO_619081_TV05161_FEB2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
J 0188
Downstream MH
J 0187
Dir. of Survey
Downstream
Length Surveyed
606 ft.
Total Length
606.1 ft.
Structural Index
3
Structural Quick
3W00
Structural Rating
360
O&M Index
2
O&M Quick
2W00
O&M Rating
240
Overall Index
3
Overall Quick
Overall Rating
600
Pipe schematic from manhole J 0188 to J 0187
MH: J 0188MH: J 0187downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 01882.6 ft. MGO - General Observation - MAGNESIUM H.O. START2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start190.4 ft. MGP - General Photograph360.3 ft. MGP - General Photograph601.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish601.8 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH601.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish606.1 ft. AMH - Downstream Manhole, Survey Ends - J 0187

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Photograph

    190.4 ft. - General Photograph

  • General Photograph

    360.3 ft. - General Photograph

Observations (12)

DistanceCodeObservation
2.6MGOMAGNESIUM H.O. START
0MWL
190.4MGP
601.8SAV
2.6SAV
601.8MGOMAGNEZIUM H.O. FINISH
360.3MGP
606.1AMHJ 0187
0MWM
2.6DAGS
0AMHJ 0188
601.8DAGS

Properties (6)

additional_info
SC318636
custom_field_two
3
customer
LACSD
datetime
2017-01-26T00:42:58-08:00
documentation
PRO PIPE
is_lateral_inspection
false