Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2017, 07:07 AM
  • J 0184_J 0183 _01262017_232522.mp4

Date
01/26/2017
W/O
619081
Weather
Dry
Operator/Surveyor
R.VARGAS
Sewer ID
Z00055
PipeID
P11423
Time
11:07 PM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4095
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
SAN PEDRO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47A
Purpose
Routine Assessment
Project
WO_619081_TV05161_FEB2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
J 0184
Downstream MH
J 0183
Dir. of Survey
Downstream
Length Surveyed
308.3 ft.
Total Length
308.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole J 0184 to J 0183
MH: J 0184MH: J 0183downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 01840 ft. MWL - Water Level, 25 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 04 to 08 o'clock, Start - DEBRIS NOT VISIBLE2.1 ft. MGO - General Observation - MAGNEZIUM H.O COATING start2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start101.7 ft. MGP - General Photograph176.5 ft. LR - Alignment Right, 10 %303.1 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 04 to 08 o'clock, Finish - DEBRIS NOT VISIBLE303.1 ft. MGO - General Observation - MAGNEZIUM H.O COATING finish303.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish303.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish308.3 ft. AMH - Downstream Manhole, Survey Ends - J 0183

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    101.7 ft. - General Photograph

Observations (14)

DistanceCodeObservation
0MWM
303.1OBZDEBRIS NOT VISIBLE
303.1MGOMAGNEZIUM H.O COATING finish
2.1DAGS
0AMHJ 0184
101.7MGP
0MWL
303.1SAV
303.1DAGS
308.3AMHJ 0183
2.1OBZDEBRIS NOT VISIBLE
2.1MGOMAGNEZIUM H.O COATING start
176.5LR
2.1SAV

Properties (6)

additional_info
SC318636
custom_field_two
3
customer
LACSD
datetime
2017-01-26T23:07:19-08:00
documentation
PRO PIPE
is_lateral_inspection
false