Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2020, 11:26 AM
  • 22 1017_22 1016_11162020_034727.mp4

Date
11/16/2020
W/O
854940
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00819
PipeID
P17386
Time
3:26 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8199
Sewer Name
LORAINE TRUNK
City
GLENDORA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_854940_TV22109_OCT2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 1016
Downstream MH
22 1017
Dir. of Survey
Upstream
Length Surveyed
448.4 ft.
Total Length
448.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 22 1016 to 22 1017
MH: 22 1016MH: 22 1017upstream0 ft. MGO - General Observation - ROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Ends - 22 10170 ft. MGO - General Observation - CONNECTION AT MH 10 OCLOCK2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish45.4 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"57.2 ft. MGO - General Observation - MAG COATING THROUGHOUT68.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"90 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"192.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"225.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"298 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"326.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"350.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"375.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"398.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"427.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"444 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start446.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start448.4 ft. MWM - Water Mark, 25 %of cross sectional area448.4 ft. MGO - General Observation - ROACHES IN MH448.4 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK448.4 ft. AMH - Downstream Manhole, Survey Begins - 22 1016448.4 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (5)

  • General Observation - ROACHES IN MH

    0 ft. - General Observation - ROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT

    391.2 ft. - General Observation - MAG COATING THROUGHOUT

  • General Observation - ROACHES IN MH

    448.4 ft. - General Observation - ROACHES IN MH

Observations (28)

DistanceCodeObservation
358.4TF
446.3SAP
175.1TFC
2DAGS
403TFA
391.2MGOMAG COATING THROUGHOUT
256.3TF
20.9TFA
72.9TFA
199.7TFC
0MWM
446.3DAGS
448.4MGOROACHES IN MH
448.4AMH22 1017
97.7TFC
379.6TFA
0MGOROACHES IN MH
49.6TFC
0MGOCONNECTION AT MH 3 OCLOCK
0AMH22 1016
330.6TFC
223.2TFA
0MWL
122.1TFC
150.4TFC
276.6TFC
4.4SAP
448.4MGOCONNECTION AT MH 10 OCLOCK

Properties (7)

additional_info
630069111620003
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2020-11-16T03:26:05-08:00
documentation
PRO PIPE
is_lateral_inspection
false