Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2020, 04:23 AM
  • 32 0138_32 0137A_10292020_213316.mp4

Date
10/29/2020
W/O
849890
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00887
PipeID
P19886
Time
9:23 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8177
Sewer Name
DISTRICT #32 MAIN TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_849890_TV32048_SEP2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
32 0138
Downstream MH
32 0137A
Dir. of Survey
Downstream
Length Surveyed
244.8 ft.
Total Length
244.8 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
144
O&M Index
2
O&M Quick
2I00
O&M Rating
96
Overall Index
3
Overall Quick
Overall Rating
240
Pipe schematic from manhole 32 0138 to 32 0137A
MH: 32 0138MH: 32 0137Adownstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 01380 ft. MWL - Water Level, 30 %of cross sectional area0.1 ft. MGO - General Observation - COCKROACHES IN MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start242.7 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish242.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish244.8 ft. MGO - General Observation - COCKROACHES IN MH244.8 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK244.8 ft. AMH - Downstream Manhole, Survey Ends - 32 0137A

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0.1 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    244.8 ft. - General Observation - COCKROACHES IN MH

Observations (11)

DistanceCodeObservation
242.7SAP
0MWM
0.1MGOCOCKROACHES IN MH
2DAGS
242.7DAGS
2SAP
0AMH32 0138
244.8MGOCOCKROACHES IN MH
0MWL
244.8MGOCONNECTION AT MH, 9 O'CLOCK
244.8AMH32 0137A

Properties (7)

additional_info
6301029200138P1
custom_field_three
SPALLING/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2020-10-29T21:23:02-07:00
documentation
PRO PIPE
is_lateral_inspection
false