- Date
- 11/23/2020
- W/O
- 855321
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00174
- PipeID
- P10750
- Time
- 1:22 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8220
- Sewer Name
- JOINT OUTFALL H - UNIT 3
- City
- PICO RIVERA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_855321_TV02323_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 57 in.
- Upstream MH
- H 0294
- Downstream MH
- H 0295
- Dir. of Survey
- Upstream
- Length Surveyed
- 298.9 ft.
- Total Length
- 298.9 ft.
- Structural Index
- 3
- Structural Quick
- 5J3J
- Structural Rating
- 556
- O&M Index
- 3
- O&M Quick
- 3K00
- O&M Rating
- 177
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 733
Pipe schematic from manhole H 0294 to H 0295 Observation photos (6)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - 85% MAG COAT

2 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - SLUDGE

28.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

154.3 ft. - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4", 8" - OPEN

298.9 ft. - Survey Abandoned - UNABLE TO CONTINUE DUE TO SLUDGE