Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 24, 2020, 10:59 AM
  • 01 0719_01 0718_11242020_030540.mp4

Date
11/24/2020
W/O
855491
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00195
PipeID
P01428
Time
2:59 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8315
Sewer Name
BULLIS ROAD RELIEF TRUNK, SECTION 1
City
LYNWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
14
Purpose
Routine Assessment
Project
WO_855491_TV01002_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
33 in.
Upstream MH
01 0719
Downstream MH
01 0718
Dir. of Survey
Downstream
Length Surveyed
163.6 ft.
Total Length
163.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 01 0719 to 01 0718
MH: 01 0719MH: 01 0718downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 07190 ft. MWM - Water Mark, 30 %of cross sectional area163.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0718

Observations (4)

DistanceCodeObservation
163.6AMH01 0718
0MWL
0AMH01 0719
0MWM

Properties (5)

additional_info
630075112320204
customer
1
datetime
2020-11-24T02:59:27-08:00
documentation
PROPIPE
is_lateral_inspection
false