- Date
- 11/13/2020
- W/O
- 854908
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00640
- PipeID
- P13117
- Time
- 12:50 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8209
- Sewer Name
- ALLEN AVENUE TRUNK, SECTION 3
- City
- SAN GABRIEL
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- WO_854908_TV16073_OCT2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 16 0027
- Downstream MH
- 16 0026
- Dir. of Survey
- Downstream
- Length Surveyed
- 333.9 ft.
- Total Length
- 333.9 ft.
- Structural Index
- 3
- Structural Quick
- 3L2L
- Structural Rating
- 330
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 330
Pipe schematic from manhole 16 0027 to 16 0026 Observation photos (2)

3.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start