Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 25, 2020, 06:58 AM
  • 18 0796_18 0795_11242020_232612.mp4

Date
11/24/2020
W/O
855318
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00706
PipeID
P14654
Time
10:58 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8317
Sewer Name
SO WHITTIER OUTFALL TR, SECTS 1,2,3,&4
City
SANTA FE SPRINGS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_855318_TV18182_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0796
Downstream MH
18 0795
Dir. of Survey
Downstream
Length Surveyed
312.5 ft.
Total Length
312.5 ft.
Structural Index
3
Structural Quick
4332
Structural Rating
24
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole 18 0796 to 18 0795
MH: 18 0796MH: 18 0795downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - HEAVY STEAM0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 07960 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK3.8 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES7.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES11 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES19.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES50.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start72.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish72.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start72.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish98.4 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start207.7 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish287.1 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES, Start310.9 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES, Finish311 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: YES312.5 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish312.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0795312.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (10)

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    3.8 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    7.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    11 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    19.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    47.6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    50.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    72.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Fine,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    98.4 ft. - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES, Start

    287.1 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 04 to 05 o'clock,  , within 8 inches of joint: YES

    311 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
0MWL
311DAGS
0MGOCONNECTION AT MH 9 O'CLOCK
0MGOHEAVY STEAM
98.4DSF
310.9FM
207.7FM
287.1FM
312.5DSF
19.5CM
47.6FM
3.8CL
0MWM
0AMH18 0796
72.7FL
7.9CL
72.8CM
312.5AMH18 0795
11CL
312.5MGOCONNECTION AT MH 3 O'CLOCK
72.7FM
0MGOCONNECTION AT MH 3 O'CLOCK
50.4FL

Properties (7)

additional_info
630075112420202
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2020-11-24T22:58:05-08:00
documentation
PROPIPE
is_lateral_inspection
false