- Date
- 10/26/2020
- W/O
- 849588
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00653
- PipeID
- P23082
- Time
- 1:44 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8171
- Sewer Name
- CHAPEL AVENUE TRUNK, SECTION 2
- City
- SAN MARINO
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- WO_849588_TV16015_SEP2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 6 in.
- Width
- 8 in.
- Upstream MH
- 16 0271
- Downstream MH
- 16 0270
- Dir. of Survey
- Downstream
- Length Surveyed
- 345.6 ft.
- Total Length
- 345.6 ft.
- Structural Index
- 3
- Structural Quick
- 3M00
- Structural Rating
- 204
- O&M Index
- 2
- O&M Quick
- 413G
- O&M Rating
- 256
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 460
Pipe schematic from manhole 16 0271 to 16 0270 Observation photos (3)

2 ft. - Shape or Size Change, -, 6"

4.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

23 ft. - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR, Start