Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2020, 08:42 AM
  • C 0665_C 0664_11042020_005536.mp4

Date
11/04/2020
W/O
854871
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00266
PipeID
P20525
Time
12:42 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8145
Sewer Name
JOINT OUTFALL C - UNIT 3F
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_854871_TV29113_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
C 0665
Downstream MH
C 0664
Dir. of Survey
Downstream
Length Surveyed
319.7 ft.
Total Length
319.7 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole C 0665 to C 0664
MH: C 0665MH: C 0664downstream0 ft. AMH - Upstream Manhole, Survey Begins - C 06650 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0.1 ft. MWM - Water Mark, 15 %of cross sectional area3.9 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES6.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start88.9 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"137.7 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"191 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"239 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"292.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"319.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish319.7 ft. AMH - Downstream Manhole, Survey Ends - C 0664

Observation photos (4)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    3.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    88.9 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    137.7 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (13)

DistanceCodeObservation
88.9TB
319.7CM
3.9CM
0AMHC 0665
191TFC
0MGOCONNECTION AT MH 9 O'CLOCK
292.4TFC
319.7AMHC 0664
0MWL
137.7TB
6.2CM
239TF
0.1MWM

Properties (8)

additional_info
6301103200075P2
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-11-04T00:42:42-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
37482