Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 27, 2017, 04:21 PM
  • 22 0875_22 0874_10272017_100430.mp4

Date
10/27/2017
W/O
0670869
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00798
PipeID
P17244
Time
9:21 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
G7545
Sewer Name
22 CONEY TRUNK, SECTION 1
City
AZUSA
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
20171027SHO_CONEY_TRUNK_SECTION_1
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Upstream MH
22 0875
Downstream MH
22 0874
Dir. of Survey
Downstream
Length Surveyed
333.9 ft.
Total Length
333.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0875 to 22 0874
MH: 22 0875MH: 22 0874downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10050 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.2 ft. MGO - General Observation - 80% MAG COAT INTACT30 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"69.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"101.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"141.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"174.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"222.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"254.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"302.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"318.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"331.3 ft. MGO - General Observation - Grease Throughout The Reach (5%)333.9 ft. AMH - Downstream Manhole, Survey Ends - 1020

Observations (15)

DistanceCodeObservation
333.9AMH1020
318.7TFC
0AMH1005
101.7TFC
0MWM
2.2MGO80% MAG COAT INTACT
222.5TFC
69.5TFC
141.8TFC
0MWL
331.3MGOGrease Throughout The Reach (5%)
30TFC
254.3TFC
302.6TFC
174.3TFC

Properties (6)

custom_field_three
80% MAG COAT INTACT
custom_field_two
5
customer
LACSD
datetime
2017-10-27T09:21:02-07:00
documentation
OBREGON, IGNACIO, FRANKLIN, BRAR
is_lateral_inspection
false