- Date
- 08/10/2018
- W/O
- 0722652
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00658
- PipeID
- P21483
- Time
- 12:19 PM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7783
- Sewer Name
- 16 DISTRICT #16 MAIN RELIEF TRUNK
- City
- ALHAMBRA
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- 20180810SHO_DISTRICT_16_MAIN_RELIEF_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- 16 0388
- Downstream MH
- B 1236
- Dir. of Survey
- Downstream
- Length Surveyed
- 176.4 ft.
- Total Length
- 176.4 ft.
- Structural Index
- 1
- Structural Quick
- 1100
- Structural Rating
- 1
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 3
Pipe schematic from manhole 16 0388 to B 1236