Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2018, 12:41 PM
  • 08 0291_08 0290_8132018_054444.mp4

Date
08/13/2018
W/O
0722683
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00012
PipeID
P00335
Time
5:41 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0948
Sewer Name
08 JAMES STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
08132018VMR_JAMES_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0291
Downstream MH
08 0290
Dir. of Survey
Downstream
Length Surveyed
336.1 ft.
Total Length
336.1 ft.
Structural Index
2
Structural Quick
3A22
Structural Rating
40
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
40
Pipe schematic from manhole 08 0291 to 08 0290
MH: 08 0291MH: 08 0290downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 4" - Open0 ft. AMH - Upstream Manhole, Survey Begins - 05:43 AM0 ft. MWL - Water Level, 20 %of cross sectional area6.2 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES14.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES26.1 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES99.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"99.3 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES128.8 ft. CM - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES137.8 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES144 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES149.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES170.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES189.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"191.7 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES200.3 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES215.4 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES224.3 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES233.3 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES239.4 ft. CC - Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES243.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - Open260.5 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES275.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES301.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"319.8 ft. CM - Crack Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES336.1 ft. AMH - Downstream Manhole, Survey Ends - 06:22 AM

Observations (27)

DistanceCodeObservation
224.3CC
336.1AMH06:22 AM
14.1CM
319.8CM
99.3TFA
215.4CC
137.8CC
233.3CM
0MWM
6.2CM
243.9TFOpen
239.4CC
200.3CC
0TFOpen
0AMH05:43 AM
128.8CM
189.8TFC
26.1CC
170.9CL
0MWL
260.5CL
99.3CM
144CM
149.7CM
275.6CM
301.4TFC
191.7CM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-08-13T05:41:30-07:00
documentation
REVELES, OLIVER, YOUNG
is_lateral_inspection
false