Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 13, 2018, 08:14 AM
  • 08 0297_08 0296_8132018_013005.mp4

Date
08/13/2018
W/O
0722683
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00012
PipeID
P00342
Time
1:14 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0947
Sewer Name
08 JAMES STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Routine Assessment
Project
08132018VMR_JAMES_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
08 0297
Downstream MH
08 0296
Dir. of Survey
Downstream
Length Surveyed
355.2 ft.
Total Length
355.2 ft.
Structural Index
2
Structural Quick
3A2C
Structural Rating
79
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
83
Pipe schematic from manhole 08 0297 to 08 0296
MH: 08 0297MH: 08 0296downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01:15 AM13.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES20.8 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES23.8 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES31.8 ft. CC - Crack Circumferential, from 09 to 02 o'clock, within 8 inches of joint: YES41.8 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES47.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES56.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES65.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES72 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES76.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - Open78.5 ft. MWL - Water Level, 60 %of cross sectional area80.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open82.1 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES90.5 ft. MWL - Water Level, 40 %of cross sectional area94.2 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES98 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES122.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES130.3 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES130.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES146.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES146.1 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES154.2 ft. CC - Crack Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES162.2 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES173 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES185.3 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES186.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"190.7 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES193.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES196.6 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES199.6 ft. CM - Crack Multiple, from 01 to 02 o'clock, within 8 inches of joint: YES202.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES211.7 ft. CC - Crack Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES217.6 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES223.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES238.7 ft. CC - Crack Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES242.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES246.8 ft. CC - Crack Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES262.6 ft. CC - Crack Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES278.8 ft. CC - Crack Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES292.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"293.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES297.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES301.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES305.5 ft. CC - Crack Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES313.6 ft. CC - Crack Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES317.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES349.6 ft. CC - Crack Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES355.2 ft. AMH - Downstream Manhole, Survey Ends - 02:21 AM

Observations (51)

DistanceCodeObservation
162.2CM
293.4CL
317.5CL
146.1CL
65.6CM
130.3CL
297.4CL
242.9CL
355.2AMH02:21 AM
122.1CM
20.8CM
90.5MWL
0MWL
193.8CL
47.5CL
186.2TFC
217.6CL
211.7CC
305.5CC
130.3CL
13.1CM
41.8CL
94.2CC
199.6CM
23.8CM
31.8CC
313.6CC
76.5TFOpen
185.3CM
173CL
78.5MWL
278.8CC
82.1CC
154.2CC
72CL
202.5CL
349.6CC
98CL
0MWM
246.8CC
56.5CL
238.7CC
146.1CL
190.7CC
0AMH01:15 AM
292.1TFC
301.4CL
262.6CC
80.8TFOpen
223.5CM
196.6CM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2018-08-13T01:14:00-07:00
documentation
REVELES, OLIVER, YOUNG
is_lateral_inspection
false