Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 23, 2020, 10:26 AM
  • 05 0806_05 0805 _11232020_023338.mp4

Date
11/23/2020
W/O
854935
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00553
PipeID
P06037
Time
2:26 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8311
Sewer Name
MANCHESTER-VERMONT DIVERSION EXTENSION TRUNK
City
S. LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_854935_TV05320_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
05 0806
Downstream MH
05 0805
Dir. of Survey
Downstream
Length Surveyed
144.6 ft.
Total Length
144.6 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 0806 to 05 0805
MH: 05 0806MH: 05 0805downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 08060 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start13 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start144.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish144.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish144.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0805

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH05 0806
2.5DAGS
144.6FM
144.6DAGS
13FM
0MWM
0MWL
144.6AMH05 0805

Properties (7)

additional_info
630075112320001
custom_field_three
MULTIPLE CRACKS/ FRACTURE'S
custom_field_two
2
customer
1
datetime
2020-11-23T02:26:10-08:00
documentation
PROPIPE
is_lateral_inspection
false