Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2018, 07:00 PM
  • 05 1174_05 0102_892018_004928.mp4

Date
08/09/2018
W/O
0717904
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00514
PipeID
P06412
Time
12:00 PM
Certificate
U11506022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0944
Sewer Name
05 ROSECRANS AVENUE TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
08062018VMR_ROSECRANS_AVE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
05 1174
Downstream MH
05 0102
Dir. of Survey
Downstream
Length Surveyed
314.8 ft.
Total Length
314.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 1174 to 05 0102
MH: 05 1174MH: 05 0102downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:48 AM1.8 ft. LFB - Lining Failure Blistered, from 12 to 02 o'clock, within 8 inches of joint: NO42.1 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open92.2 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 4"142.1 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open145.8 ft. LFZ - Lining Failure Other, at 10 o'clock, within 8 inches of joint: NO - Sealer Tape is peeling off192.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open242.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open292.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open314.8 ft. AMH - Downstream Manhole, Survey Ends - 01:15 AM

Observation photos (2)

  • Lining Failure Blistered, from 12 to 02 o'clock, within 8 inches of joint: NO

    1.8 ft. - Lining Failure Blistered, from 12 to 02 o'clock, within 8 inches of joint: NO

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open

    292.5 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - Open

Observations (12)

DistanceCodeObservation
1.8LFB
42.1TBOpen
0MWM
0MWL
314.8AMH01:15 AM
0AMH12:48 AM
242.7TBOpen
92.2TBA
292.5TBOpen
145.8LFZSealer Tape is peeling off
192.7TBOpen
142.1TBOpen

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2018-08-09T12:00:00-07:00
documentation
REVELES, OLIVER III, YOUNG
is_lateral_inspection
false