- Date
- 11/24/2020
- W/O
- 848810
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00177
- PipeID
- P10851
- Time
- 11:34 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8222
- Sewer Name
- H JOINT OUTFALL H - UNIT 5A
- City
- BASSETT
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- RFIR_WO_848810_TV15130_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Width
- 54 in.
- Upstream MH
- H 0417A
- Downstream MH
- H 0417
- Dir. of Survey
- Downstream
- Length Surveyed
- 146.6 ft.
- Total Length
- 146.6 ft.
- Structural Index
- 2
- Structural Quick
- 3E2E
- Structural Rating
- 142
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 146
Pipe schematic from manhole H 0417A to H 0417 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COAT

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

5 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 10"

46.6 ft. - Alignment Left, 30 %