Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2020, 10:23 AM
  • 22 1015_22 1014_11162020_024142.mp4

Date
11/16/2020
W/O
855314
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00819
PipeID
P17384
Time
2:23 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8198
Sewer Name
LORAINE TRUNK
City
GLENDORA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_855314_TV22159_OCT2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 1015
Downstream MH
22 1014
Dir. of Survey
Downstream
Length Surveyed
395.2 ft.
Total Length
395.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
3321
O&M Rating
14
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole 22 1015 to 22 1014
MH: 22 1015MH: 22 1014downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 10150 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - MAG COATING THROUGHOUT17.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start17.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"148.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"222.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"266.1 ft. RML - Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES266.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"317.9 ft. RFJ - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES323.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"323.5 ft. RML - Roots Medium Lateral, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES362.6 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES375 ft. RMJ - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR376.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"376.5 ft. RFL - Roots Fine Lateral, from 02 to 04 o'clock394.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish394.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish395.2 ft. MGO - General Observation - ROACHES IN MH395.2 ft. AMH - Downstream Manhole, Survey Ends - 22 1014

Observation photos (10)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES

    266.1 ft. - Roots Medium Lateral, from 01 to 05 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

    317.9 ft. - Roots Fine Joint, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Roots Medium Lateral, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

    323.5 ft. - Roots Medium Lateral, from 01 to 05 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

    362.6 ft. - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

  • Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR

    375 ft. - Roots Medium Joint, from 03 to 09 o'clock, 15 %, within 8 inches of joint: YESR

  • Roots Fine Lateral, from 02 to 04 o'clock

    376.5 ft. - Roots Fine Lateral, from 02 to 04 o'clock

  • General Observation - ROACHES IN MH

    395.2 ft. - General Observation - ROACHES IN MH

Observations (24)

DistanceCodeObservation
317.9RFJ
376.5TFA
395.2MGOROACHES IN MH
266.1RML
17.7SAP
323.5TFA
0MWL
148.3TF
2DAGS
323.5RML
17.7TFA
376.5RFL
0AMH22 1015
362.6RFJ
222.1TFC
395.2AMH22 1014
71.2TF
394.2SAP
2MGOMAG COATING THROUGHOUT
184.6TFA
266.4TFA
375RMJ
0MWM
394.2DAGS

Properties (7)

additional_info
630069111620002
custom_field_three
PROJECTING AGGREGATE/ROOTS
custom_field_two
3
customer
1
datetime
2020-11-16T02:23:05-08:00
documentation
PRO PIPE
is_lateral_inspection
false