Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 5, 2020, 12:41 PM
  • 05 0315_05 0314_1252020_044432.mp4

Date
12/05/2020
W/O
0859963
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00500
PipeID
P05549
Time
4:41 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1652
Sewer Name
05 OAK STREET-CENTER AVENUE RELOCATION TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
06
Purpose
Routine Assessment
Project
20201205MDM_OAK_STREET_CENTER_AVENUE_RELOCATION_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 0315
Downstream MH
05 0314
Dir. of Survey
Downstream
Length Surveyed
299.8 ft.
Total Length
299.8 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 0315 to 05 0314
MH: 05 0315MH: 05 0314downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LISTERING PEELING CONCRETE85.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, - BLISTERING PEELING CONCRETE171 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE299.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE299.8 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES,  - BLISTERING PEELING CONCRETE

    85.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    171 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

Observations (9)

DistanceCodeObservation
171SSSBLISTERING PEELING CONCRETE
0MWM
85.6SSSBLISTERING PEELING CONCRETE
299.8AMH5:05AM
299.3SSSBLISTERING PEELING CONCRETE
2SSSLISTERING PEELING CONCRETE
0AMH4:45AM
0MWL
0MGOConn. @ Mh, 9 O' Clock. Active

Properties (6)

custom_field_three
BLISTERING PEELING C0NCRETE
custom_field_two
4
customer
LACSD
datetime
2020-12-05T04:41:54-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection