Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2020, 12:33 PM
  • 05 0695_05 0694_1272020_044009.mp4

Date
12/07/2020
W/O
0864832
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00523
PipeID
P05927
Time
4:33 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1653
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
20201207MDM_SOUTH_INGLEWOOD_ORANGE_AVENUE_TRUNK_EXTENSION_2
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.579999923706055 in.
Upstream MH
05 0695
Downstream MH
05 0694
Dir. of Survey
Downstream
Length Surveyed
261.5 ft.
Total Length
261.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 0695 to 05 0694
MH: 05 0695MH: 05 0694downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:35AM0 ft. MWL - Water Level, 10 %of cross sectional area25.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - Open77 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - Open125.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open130.4 ft. MGO - General Observation - 7.5" VCP-PVCP177.5 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: NO, 6" - Open-25%226.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open261.5 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM

Observation photos (1)

  • General Observation - 7.5" VCP-PVCP

    130.4 ft. - General Observation - 7.5" VCP-PVCP

Observations (10)

DistanceCodeObservation
226.2TBOpen
130.4MGO7.5" VCP-PVCP
0MWM
261.5AMH4:55AM
77TBOpen
125.7TBOpen
0AMH4:35AM
177.5TBDOpen-25%
0MWL
25.9TBOpen

Properties (7)

custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2020-12-07T04:33:47-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining
PVCP-Folded/Reformed