Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 10, 2018, 07:52 AM
  • 02 0893_02 0782_9102018_025342.mp4

Date
09/10/2018
W/O
0726333
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00252
PipeID
P18909
Time
12:52 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0971
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Routine Assessment
Project
20180910MDM_DOWNEY_BELLFLOWER_DIVERSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
02 0782
Downstream MH
02 0893
Dir. of Survey
Upstream
Length Surveyed
7 ft.
Total Length
7 ft.
Structural Index
3
Structural Quick
5142
Structural Rating
27
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole 02 0782 to 02 0893
MH: 02 0782MH: 02 0893upstream0 ft. AMH - Upstream Manhole, Survey Ends - 3:15AM- STOPLOG IN PLACE OR STUB1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL2.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open3.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL3.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL4 ft. B - Broken, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - SLIGHT5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - SLIGHT7 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active7 ft. AMH - Downstream Manhole, Survey Begins - 2:55AM7 ft. MWM - Water Mark, 20 %of cross sectional area7 ft. MWL - Water Level, 0 %of cross sectional area - STOPLOG UPSTREAM

Observation photos (6)

  • Broken, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT  FRACTURE

    3 ft. - Broken, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    3.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

  • Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE

    4 ft. - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open

    4 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL

    4.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SL

  • Upstream Manhole, Survey Ends - 3:15AM- STOPLOG IN PLACE OR STUB

    7 ft. - Upstream Manhole, Survey Ends - 3:15AM- STOPLOG IN PLACE OR STUB

Observations (15)

DistanceCodeObservation
4FCHAIRLINE
4TFOpen
6TFOpen
7AMH3:15AM- STOPLOG IN PLACE OR STUB
5FLSL
0MGOConn. @ Mh, 9 O' Clock. Active
0AMH2:55AM
3.5FLSL
3BSLIGHT FRACTURE
2FLSLIGHT
4.5FMSL
0MWM
2FLSLIGHT
0MWLSTOPLOG UPSTREAM
3.5FMSL

Properties (7)

additional_info
REVERSE INSPECTION
custom_field_three
BROKEN PIPE SLIGHT FRACTURE-MULTIPLE SLIGHT
custom_field_two
2
customer
LACSD
datetime
2018-09-10T00:52:28-07:00
documentation
MARTIN,OLIVER,BRAR
is_lateral_inspection
false