Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2019, 09:50 AM
  • Section#1_J 0222_J 0219__6142019__I0158.mp4

Date
06/14/2019
W/O
0756080
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11467
Time
2:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0158
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
48
Purpose
Capital Improvement Program Assesment
Project
20190614MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0222
Downstream MH
J 0219
Dir. of Survey
Downstream
Length Surveyed
1391.8 ft.
Total Length
1391.8 ft.
Structural Index
3
Structural Quick
5T4S
Structural Rating
1531
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
1531
Pipe schematic from manhole J 0222 to J 0219
MH: J 0222MH: J 0219downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:15AM0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE28.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE35.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERER AGG56.6 ft. MGO - General Observation - 90% MAG COAT FINISH91.6 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG91.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG94 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG97.1 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR104.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: NO - CIRCUM132.9 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR283.2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR502.1 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR593.7 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG597.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG617.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE940.9 ft. MGO - General Observation - GENORATOR DIED STOPPED CLIP1149.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO1297 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start1297.6 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR1391 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR1391.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE1391.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR1391.1 ft. SAV - Surface AGGERATE VISIBLE, from 08 to 04 o'clock, within 8 inches of joint: YES FINISH - SEVERE AGG1391.8 ft. AMH - Downstream Manhole, Survey Ends - 7:10AM

Observation photos (14)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    28.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERER AGG

    35.1 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERER AGG

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    91.6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    94 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    97.1 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: NO - CIRCUM

    104.3 ft. - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: NO - CIRCUM

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES,  - LONG CIRCUM REBAR

    132.9 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, - LONG CIRCUM REBAR

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    283.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    597.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE

    617.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO

    1149.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    1297 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    1297.6 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

Observations (27)

DistanceCodeObservation
1391.1SSSBLISTERING PEELING CONCRETE
940.9MGOGENORATOR DIED STOPPED CLIP
502.1SRVLONG CIRCUM REBAR
597.7SAVSEVERE AGG
1391.1SRCCIRCUM REBAR
1297SRC
0MWL
28.5SSSBLISTERING PEELING CONCRETE
1149.6SAV
1391SRCCIRCUM REBAR
593.7SAMSEVERE AGG
91.6SAVSEVERE AGG
2SSSBLISTERING PEELING CONCRETE
1391.8AMH7:10AM
56.6MGO90% MAG COAT FINISH
1297.6SRCCIRCUM REBAR
97.1SRVLONG CIRCUM REBAR
94SAMSEVERE AGG
1391.1SAVSEVERE AGG
0AMH4:15AM
104.3SRCCIRCUM
283.2SRVLONG CIRCUM REBAR
0MWM
617.4SSSBLISTERING PEELING CONCRETE
91.6SAMSEVERE AGG
132.9SRCLONG CIRCUM REBAR
35.1SAVSEVERER AGG

Properties (6)

custom_field_three
LONG & CIRCUM REBAR CORRODED
custom_field_two
1
customer
LACSD
datetime
2019-06-14T02:50:47-07:00
documentation
MARTIN,REVELES,OLIVER,SHADLER
is_lateral_inspection
false