Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 5, 2019, 02:01 PM
  • SEG#14_SEG#14_02-882_02-881_C_SI_Memo.mpg

Date
08/05/2019
W/O
764312
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
PipeID
P03449
Time
7:01 AM
Certificate
1234
System Owner
DOWNEY
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
SEG#14
City
CITY OF DOWNEY
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary
Purpose
Post-Rehabilitation Survey
Project
JOB#936 COUNTY SAN. DIST. DOWNEY TRUNK SEWER
Material
Concrete Pipe (non-reinforced)
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
02-882
Downstream MH
02-881
Dir. of Survey
Downstream
Length Surveyed
297.7 ft.
Total Length
297.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02-882 to 02-881
MH: 02-882MH: 02-881downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO53.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"139.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"158.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"161.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"163.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"256.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"297.7 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (8)

DistanceCodeObservation
53.5TFA
158.6TFA
297.7AMHPOST VIDEO
0AMHPOST VIDEO
256.9TFA
161.4TFA
139.5TBA
163.1TBA

Properties (3)

customer
DOWNEY
datetime
2019-08-05T07:01:37-07:00
is_lateral_inspection