Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 13, 2020, 08:16 AM
  • B 0718_B 0717_10132020_015359.mp4

Date
10/13/2020
W/O
849990
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00110
PipeID
P09392
Time
1:16 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8158
Sewer Name
JOINT OUTFALL B - UNIT 8G
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
08
Purpose
Routine Assessment
Project
WO_849990_TV15057_SEP2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
B 0717
Downstream MH
B 0718
Dir. of Survey
Upstream
Length Surveyed
411.6 ft.
Total Length
411.6 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
246
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
246
Pipe schematic from manhole B 0717 to B 0718
MH: B 0717MH: B 0718upstream0 ft. AMH - Upstream Manhole, Survey Ends - B 07181.2 ft. MGO - General Observation - COCKROACHES IN MH1.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish53.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"56.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"95.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"156.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"203.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"206.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"268.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"309.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"313.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"345.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"349 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"399 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"402.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"409.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start411.6 ft. MWM - Water Mark, 10 %of cross sectional area411.6 ft. MWL - Water Level, 5 %of cross sectional area411.6 ft. AMH - Downstream Manhole, Survey Begins - B 0717411.6 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (3)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    410.4 ft. - General Observation - COCKROACHES IN MH

Observations (24)

DistanceCodeObservation
98.4TFC
316.1TFA
146.4TFC
12.6TFC
102.2TFC
143.4TFC
355.1TFC
410.4MGOCOCKROACHES IN MH
62.6TFA
208.3TFA
2SAV
411.6AMHB 0718
358.3TFC
410.4SAV
255.3TFA
9.5TFC
0MWM
0MWL
65.9TFC
258.7TFC
312.4TFC
0AMHB 0717
0MGOCOCKROACHES IN MH
205.1TFC

Properties (7)

additional_info
6301012200138P1
custom_field_three
VISIBLE AGGREGATE
custom_field_two
3
customer
1
datetime
2020-10-13T01:16:07-07:00
documentation
PRO PIPE
is_lateral_inspection
false