Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 30, 2020, 10:06 AM
  • B 0713_B 0712_09302020_032519.mp4

Date
09/30/2020
W/O
849990
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00110
PipeID
P09386
Time
3:06 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8153
Sewer Name
JOINT OUTFALL B - UNIT 8G
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
08
Purpose
Routine Assessment
Project
WO_849990_TV15057_SEP2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
39 in.
Upstream MH
B 0712
Downstream MH
B 0713
Dir. of Survey
Upstream
Length Surveyed
342.4 ft.
Total Length
342.4 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
204
O&M Index
2
O&M Quick
2M00
O&M Rating
136
Overall Index
3
Overall Quick
Overall Rating
340
Pipe schematic from manhole B 0712 to B 0713
MH: B 0712MH: B 0713upstream0 ft. AMH - Upstream Manhole, Survey Begins - B 07130 ft. MGO - General Observation - COCKROACHES IN MANHOLE2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish23.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"26.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"72.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"124.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"177 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"179.8 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"228.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"280.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"283.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"286.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"340.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start340.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start340.4 ft. MGO - General Observation - MAG COATING THROUGHOUT342.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK342.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE342.4 ft. AMH - Downstream Manhole, Survey Begins - B 0712342.4 ft. MWM - Water Mark, 20 %of cross sectional area342.4 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • General Observation - COCKROACHES IN MANHOLE

    342.4 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (25)

DistanceCodeObservation
342.4AMHB 0713
162.6TBA
0MGOCONNECTION AT MH 9 O'CLOCK
266.5TFA
340.2SAV
61.6TFA
342.4MGOCOCKROACHES IN MANHOLE
315.6TFA
0MGOCOCKROACHES IN MANHOLE
318.6TFC
2DAGS
214.5TFA
2SAV
0AMHB 0712
0MWM
270TFC
340.2DAGS
217.5TFC
0MWL
59.1TFC
165.4TFC
55.6TFA
2MGOMAG COATING THROUGHOUT
116.8TFC
113.5TFA

Properties (4)

customer
1
datetime
2020-09-30T03:06:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false