- Date
- 11/16/2020
- W/O
- 855024
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00035
- PipeID
- P10160
- Time
- 9:35 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8212
- Sewer Name
- JOINT OUTFALL F - UNIT 3A
- City
- CERRITOS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39
- Purpose
- Routine Assessment
- Project
- WO_855024_TV02199_OCT2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Width
- 27 in.
- Upstream MH
- F 0072A
- Downstream MH
- F 0072
- Dir. of Survey
- Downstream
- Length Surveyed
- 98 ft.
- Total Length
- 98 ft.
- Structural Index
- 3
- Structural Quick
- 3C2C
- Structural Rating
- 90
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 94
Pipe schematic from manhole F 0072A to F 0072 Observation photos (2)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start