Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2020, 08:44 AM
  • 05 2636_05 2635 _10302020_005057.mp4

Date
10/30/2020
W/O
855371
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01146
PipeID
P25736
Time
1:44 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8142
Sewer Name
PALOS VERDES NORTH SLOPE REPLACEMENT TRUNK, SECT 1A
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_855371_TV05087_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 2636
Downstream MH
05 2635
Dir. of Survey
Downstream
Length Surveyed
235.2 ft.
Total Length
235.2 ft.
Structural Index
2
Structural Quick
2H00
Structural Rating
94
O&M Index
2
O&M Quick
2H00
O&M Rating
92
Overall Index
2
Overall Quick
Overall Rating
186
Pipe schematic from manhole 05 2636 to 05 2635
MH: 05 2636MH: 05 2635downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 26362 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start128.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"230.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES233 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish233 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish235.2 ft. AMH - Downstream Manhole, Survey Ends - 05 2635235.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (1)

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    230.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
233SSS
235.2AMH05 2635
235.2MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
233DAGS
128.7TB
2SSS
0MWM
2DAGS
230.6CL
0AMH05 2636

Properties (8)

additional_info
630102900075P1
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2020-10-30T01:44:48-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
38989