Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 30, 2020, 08:22 AM
  • 05 2660_05 2659 _10302020_002850.mp4

Date
10/30/2020
W/O
855371
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01146
PipeID
P26132
Time
1:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8142
Sewer Name
PALOS VERDES NORTH SLOPE REPLACEMENT TRUNK, SECT 1A
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_855371_TV05087_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 2660
Downstream MH
05 2659
Dir. of Survey
Downstream
Length Surveyed
281.1 ft.
Total Length
281.1 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2J00
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
114
Pipe schematic from manhole 05 2660 to 05 2659
MH: 05 2660MH: 05 2659downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 26600 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start168.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN279 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish279 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish281.1 ft. AMH - Downstream Manhole, Survey Ends - 05 2659

Observations (9)

DistanceCodeObservation
281.1AMH05 2659
0MWL
168.2TFOPEN
279DAGS
0AMH05 2660
279SSS
2DAGS
0MWM
2SSS

Properties (8)

additional_info
630102900075P1
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2020-10-30T01:22:08-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
40008