Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2020, 06:38 AM
  • 05 2655_05 2654 _11032020_230342.mp4

Date
11/03/2020
W/O
855371
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01146
PipeID
P26127
Time
10:38 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8144
Sewer Name
PALOS VERDES NORTH SLOPE REPLACEMENT TRUNK, SECT 1A
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_855371_TV05087_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
05 2655
Downstream MH
05 2654
Dir. of Survey
Downstream
Length Surveyed
370.6 ft.
Total Length
370.6 ft.
Structural Index
2
Structural Quick
2N00
Structural Rating
146
O&M Index
2
O&M Quick
2N00
O&M Rating
146
Overall Index
2
Overall Quick
Overall Rating
292
Pipe schematic from manhole 05 2655 to 05 2654
MH: 05 2655MH: 05 2654downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 26550 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start368 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish368 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish370.6 ft. AMH - Downstream Manhole, Survey Ends - 05 2654

Observations (9)

DistanceCodeObservation
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
0AMH05 2655
2DAGS
368SSS
2SSS
368DAGS
370.6AMH05 2654
0MWM

Properties (8)

additional_info
6301103200075P1
custom_field_three
RFIR NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2020-11-03T22:38:18-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
40008