Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 20, 2020, 05:16 AM
  • 02 2350_02 2349_11192020_220604.mp4

Date
11/19/2020
W/O
855025
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00290
PipeID
P20981
Time
9:16 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8307
Sewer Name
MONTEREY PARK EXTENSION RELIEF TRUNK
City
MONTEREY PARK
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_855025_TV02403_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 2350
Downstream MH
02 2349
Dir. of Survey
Downstream
Length Surveyed
295.7 ft.
Total Length
295.7 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 2350 to 02 2349
MH: 02 2350MH: 02 2349downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 2350100.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6", 6"130.4 ft. TB - Tap Break-In, at 04 o'clock, -, within 8 inches of joint: YES, 6"237.2 ft. FM - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES295.7 ft. AMH - Downstream Manhole, Survey Ends - 02 2349

Observation photos (2)

  • Tap Break-In, at 04 o'clock, -, within 8 inches of joint: YES, 6"

    130.4 ft. - Tap Break-In, at 04 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    237.2 ft. - Fracture Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
130.4TB
100.6TF
295.7AMH02 2349
0MWL
0MWM
237.2FM
0AMH02 2350

Properties (8)

additional_info
630075111920201
custom_field_three
FRACTURE
custom_field_two
3
customer
1
datetime
2020-11-19T21:16:05-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
33533