Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 7, 2019, 04:17 PM
  • 08-0363-08-0362.mpg

Date
06/07/2019
W/O
200347
Weather
Dry
Operator/Surveyor
Oscar Villarreal
Sewer ID
Z00003
PipeID
P00415
Time
9:17 AM
Certificate
U-1113-06019665
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Jetting
Media Label
04
Sewer Name
08 Davidson City Trunk
City
City of Carson, CA
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
12
Purpose
Pre-Rehabilitation Survey
Project
Davidson_City_TS_Rehab
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
18 in.
Upstream MH
08 0363
Downstream MH
08 0362
Dir. of Survey
Downstream
Length Surveyed
140.4 ft.
Total Length
140.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 08 0363 to 08 0362
MH: 08 0363MH: 08 0362downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 03630 ft. MWL - Water Level, 5 % of cross sectional area0 ft. MWL - Water Level, 5 % of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 3630 ft.51.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES82.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES108.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES109.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES126.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES126.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, 6", within 8 inches of joint: YES140.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0362140.9 ft. AMH - Downstream Manhole, Survey Ends - MH 362

Observations (13)

DistanceCodeObservation
140.4AMH08 0362
0AMH08 0363
51.7TFA
82.1TFA
0MWL
109.1TFA
126.8TFA
108.9TFA
0MWL
126.8TFA
140.9AMHMH 362
0AMHMH 363
0

Properties (3)

customer
LACSD
datetime
2019-06-07T09:17:26-07:00
is_lateral_inspection
false