Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2020, 12:14 PM
  • 16 0317_16 0316 _11122020_043949.mp4

Date
11/12/2020
W/O
855315
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00665
PipeID
P13368
Time
4:14 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8205
Sewer Name
SAN MARINO OUTFALL TRUNK
City
SAN MARINO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_855315_TV16060_OCT2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
16 0317
Downstream MH
16 0316
Dir. of Survey
Downstream
Length Surveyed
361.6 ft.
Total Length
361.6 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
201
O&M Index
2
O&M Quick
312M
O&M Rating
147
Overall Index
2
Overall Quick
Overall Rating
348
Pipe schematic from manhole 16 0317 to 16 0316
MH: 16 0317MH: 16 0316downstream0 ft. AMH - Upstream Manhole, Survey Begins - 16 03170 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start10.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"15.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"17.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"23.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start60.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"62.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"82.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"134.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"142.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"164.6 ft. OBR - Obstacles Rocks, 15 %of cross sectional area, at 06 o'clock189.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"248.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6"272 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"272.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"360.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish360.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish361.6 ft. AMH - Downstream Manhole, Survey Ends - 16 0316361.6 ft. TF - Tap Factory Made, at 06 o'clock, -, within 8 inches of joint: YES, 15"

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    23.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Obstacles Rocks, 15 %of cross sectional area, at 06 o'clock

    164.6 ft. - Obstacles Rocks, 15 %of cross sectional area, at 06 o'clock

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    272.1 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (22)

DistanceCodeObservation
17.7TFC
0AMH16 0317
142.4TF
134.8TF
272TFC
62.7TF
361.6AMH16 0316
248.6TF
361.6TF
360.8DAGS
189.3TFC
360.8CM
10.2TF
164.6OBR
82.1TF
0MWM
60.2TF
272.1TB
23.8CM
0MWL
15.3TFC
2.1DAGS

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-11-12T04:14:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false