Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 12, 2020, 09:49 AM
  • 15 0612A_15 0612A1_11122020_015858.mp4

Date
11/12/2020
W/O
855316
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00601
PipeID
P26624
Time
1:49 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8190
Sewer Name
DOUBLE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0612A
Downstream MH
15 0612A1
Dir. of Survey
Downstream
Length Surveyed
152.5 ft.
Total Length
152.5 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 15 0612A to 15 0612A1
MH: 15 0612AMH: 15 0612A1downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - ROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 15 0612A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start43.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"72.8 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES83.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.6 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"135 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"150.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish150.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish152.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0612A1152.5 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK

Observation photos (4)

  • General Observation - ROACHES IN MH

    0 ft. - General Observation - ROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    72.8 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
2DAGS
152.5AMH15 0612A1
0MGOCONNECTION AT MH 3 OCLOCK
128.6TBA
0MWM
43.7TF
150.5SAP
135TF
150.5DAGS
0MWL
152.5MGOCONNECTION AT MH 3 OCLOCK
0MGOROACHES IN MH
72.8CM
3.8SAP
0AMH15 0612A
83.3TFA

Properties (7)

additional_info
630069111220001
custom_field_three
PROJECTING AGGREGATE/CRACKS
custom_field_two
2
customer
1
datetime
2020-11-12T01:49:56-08:00
documentation
PRO PIPE
is_lateral_inspection
false