Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2020, 08:45 AM
  • 22 0754_22 0753_11302020_012714.mp4

Date
11/30/2020
W/O
0860113
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00821
PipeID
P17111
Time
12:45 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1640
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Capital Improvement Program Assesment
Project
20201130MDM_PUDDINGSTONE_TRUNK_SECTS_1_2
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0754
Downstream MH
22 0753
Dir. of Survey
Downstream
Length Surveyed
270 ft.
Total Length
270 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole 22 0754 to 22 0753
MH: 22 0754MH: 22 0753downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:25AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTEREING PEELING CONCRETE2.2 ft. MGO - General Observation - MAG COAT 98% START2.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDERE MAG COAT14.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDER MAG COAT18.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped66.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE UNDER MAG COAT70.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open110 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG UNDER MAG COAT118.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped170.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open218.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped262.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped269.3 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG UNDER MAG COAT269.3 ft. MGO - General Observation - 98% MAG COAT FINISH269.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVRER AGG UNDER MAG COAT269.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE UNDER MAG COAT270 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (6)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTEREING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTEREING PEELING CONCRETE

  • General Observation - MAG COAT 98% START

    2.2 ft. - General Observation - MAG COAT 98% START

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDERE MAG COAT

    2.2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDERE MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDER MAG COAT

    14.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG UNDER MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE UNDER MAG COAT

    66.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - BLISTERING PEELING CONCRETE UNDER MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG UNDER MAG COAT

    110 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG UNDER MAG COAT

Observations (20)

DistanceCodeObservation
18.1TFCCapped
269.3SAMSEVERE AGG UNDER MAG COAT
218.7TFCCapped
110SAPSEVERE AGG UNDER MAG COAT
262.9TFCCapped
14.3SAPSEVERE AGG UNDER MAG COAT
0AMH1:25AM
269.3MGO98% MAG COAT FINISH
66.8SSSBLISTERING PEELING CONCRETE UNDER MAG COAT
70.4TFOpen
269.3SAPSEVRER AGG UNDER MAG COAT
2SSSBLISTEREING PEELING CONCRETE
270AMH1:45AM
170.5TFOpen
269.3SSSBLISTERING PEELING CONCRETE UNDER MAG COAT
2.2MGOMAG COAT 98% START
0MWM
2.2SAMSEVERE AGG UNDERE MAG COAT
0MWL
118.3TFCCapped

Properties (6)

custom_field_three
SEVERE AGG MISSING - M98% MAG COAT
custom_field_two
2
customer
LACSD
datetime
2020-11-30T00:45:29-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false