- Date
- 10/14/2020
- W/O
- 849554
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00798
- PipeID
- P17244
- Time
- 1:38 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8160
- Sewer Name
- CONEY TRUNK, SECTION 1
- City
- AZUSA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_849554_TV22103_SEP2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0875
- Downstream MH
- 22 0874
- Dir. of Survey
- Downstream
- Length Surveyed
- 339 ft.
- Total Length
- 339 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 134
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 134
Pipe schematic from manhole 22 0875 to 22 0874 Observation photos (2)

2 ft. - General Observation - MAG COATING THROUGHOUT

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start