Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 23, 2020, 04:55 PM
  • 01 0114_01 0113_11232020_105346.mp4

Date
11/23/2020
W/O
0849682
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00203
PipeID
P01180
Time
8:55 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1637
Sewer Name
01 COMPTON CREEK EXTENSION TRUNK, SECTION 1
City
LA
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
15
Purpose
Maintenance Related
Project
20201123SHO_COMPTON_CREEK_EXTENSION_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
01 0114
Downstream MH
01 0113
Dir. of Survey
Downstream
Length Surveyed
298.5 ft.
Total Length
298.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 01 0114 to 01 0113
MH: 01 0114MH: 01 0113downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - GREASE EVAL. ONLY0 ft. MWM - Water Mark, 45 %of cross sectional area2.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLIGHT GREASE298.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish298.5 ft. AMH - Downstream Manhole, Survey Ends - MH 0113

Observations (6)

DistanceCodeObservation
0MWL
0AMHGREASE EVAL. ONLY
0MWM
298.5DAGS
298.5AMHMH 0113
2.1DAGSSLIGHT GREASE

Properties (7)

additional_info
GREASE EVAL.
custom_field_three
GREASE EVAL. ONLY
custom_field_two
5
customer
LACSD
datetime
2020-11-23T08:55:24-08:00
documentation
OBREGON, RAMIREZ, BRAR, IGNACIO
is_lateral_inspection