- Date
- 11/19/2020
- W/O
- 0855054
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00228
- PipeID
- P01753
- Time
- 3:57 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1630
- Sewer Name
- JOINT OUTFALL G-UNIT 9 TRUNK
- City
- SOUTH GATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 11
- Purpose
- Capital Improvement Program Assesment
- Project
- 20201118MDM_JOINT_OUTFALL_G_UNIT_9_TRUNK
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- G 0317
- Downstream MH
- G 0316
- Dir. of Survey
- Downstream
- Length Surveyed
- 56.9 ft.
- Total Length
- 56.9 ft.
- Structural Index
- 5
- Structural Quick
- 5341
- Structural Rating
- 19
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 24
Pipe schematic from manhole G 0317 to G 0316 Observation photos (5)

2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES

2 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM

2 ft. - General Observation - 40% MISSING TILES

29.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

41.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM