Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2020, 12:25 PM
  • 18 0940_18 0938_11212020_043222.mp4

Date
11/21/2020
W/O
0860424
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00701
PipeID
P14792
Time
4:25 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1635R
Sewer Name
18 SCOTT AVENUE RELIEF TRUNK
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Maintenance Related
Project
20201121MDM_SCOTT_AVENUE_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
18 0940
Downstream MH
18 0938
Dir. of Survey
Downstream
Length Surveyed
288 ft.
Total Length
288 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0940 to 18 0938
MH: 18 0940MH: 18 0938downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM45.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open129.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open147.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active288 ft. AMH - Downstream Manhole, Survey Ends - 4:50AM

Observations (8)

DistanceCodeObservation
0MWL
0MGOConn. @ Mh, 9 O' Clock. Active
0MWM
288AMH4:50AM
129.7TFOpen
45.6TFOpen
0AMH4:30AM
147.6TFActive

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-11-21T04:25:59-08:00
documentation
MARTIN,OLIVER 111,RUVALCABA
is_lateral_inspection
false