Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2020, 11:05 AM
  • 18 0942_18 0941_11212020_030838.mp4

Date
11/21/2020
W/O
0860424
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00701
PipeID
P14789
Time
3:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1635R
Sewer Name
18 SCOTT AVENUE RELIEF TRUNK
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Maintenance Related
Project
20201121MDM_SCOTT_AVENUE_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.519999980926514 in.
Upstream MH
18 0942
Downstream MH
18 0941
Dir. of Survey
Downstream
Length Surveyed
180 ft.
Total Length
180 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3111
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 18 0942 to 18 0941
MH: 18 0942MH: 18 0941downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:05AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWL - Water Level, 5 %of cross sectional area89 ft. RFC - Roots Fine Connection, from 02 to 05 o'clock, within 8 inches of joint: NO - 1%89 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 6" - Open-5% ROOTS180 ft. AMH - Downstream Manhole, Survey Ends - 3:25AM

Observations (7)

DistanceCodeObservation
0MWM
180AMH3:25AM
89RFC1%
0AMH3:05AM
0MGOConn. @ Mh, 9 O' Clock. Active
89TBDOpen-5% ROOTS
0MWL

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-11-21T03:05:19-08:00
documentation
MARTIN,OLIVER 111,RUVALCABA
is_lateral_inspection
false