Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 19, 2020, 05:34 PM
  • 3_1_1_19112020_093719.mp4

Date
11/19/2020
W/O
0844257
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00177
PipeID
P10832
Time
9:34 AM
Certificate
U-415-06024039
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0360
Sewer Name
JOINT OUTFALL H - UNIT 5A
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
20201118DF_JOINT_OUTFALL_H_UNIT_5A
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
H 0417
Downstream MH
H 0416
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
5
Overall Quick
Overall Rating
9
Pipe schematic from manhole H 0417 to H 0416
MH: H 0417MH: H 0416downstream0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 9:35 AM2 ft. LD - Alignment Down, 45 %2 ft. MSA - Survey Abandoned - HIGH WATER

Observations (5)

DistanceCodeObservation
0MWM
0MWL
0AMH9:35 AM
2LD
2MSAHIGH WATER

Properties (6)

additional_info
VIEW OF THE DOWNLEG FROM THE U/S SIPHON
custom_field_two
5
customer
1
datetime
2020-11-19T09:34:04-08:00
documentation
FRANKLIN, GNACIO, RAMIREZ
is_lateral_inspection
false