- Date
- 11/12/2020
- W/O
- 854911
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00601
- PipeID
- P12539
- Time
- 4:01 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8191
- Sewer Name
- DOUBLE AVENUE TRUNK
- City
- TEMPLE CITY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_854911_TV15183_OCT2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 15 0607
- Downstream MH
- 15 0606
- Dir. of Survey
- Downstream
- Length Surveyed
- 91.6 ft.
- Total Length
- 91.6 ft.
- Structural Index
- 3
- Structural Quick
- 3B2B
- Structural Rating
- 85
- O&M Index
- 2
- O&M Quick
- 2C00
- O&M Rating
- 36
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 121
Pipe schematic from manhole 15 0607 to 15 0606 Observation photos (4)

0 ft. - General Observation - ROACHES IN MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

4.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

89.7 ft. - General Observation - ROACHES IN MH