Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 25, 2020, 09:32 AM
  • 08 0169_08 0168_09252020_025853.mp4

Date
09/25/2020
W/O
850134
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00009
PipeID
P00226
Time
2:32 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8049
Sewer Name
GRACE STREET TRUNK, SECTION 1
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
WO_850134_TV08021_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
08 0169
Downstream MH
08 0168
Dir. of Survey
Downstream
Length Surveyed
287.7 ft.
Total Length
287.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 08 0169 to 08 0168
MH: 08 0169MH: 08 0168downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01690 ft. MWL - Water Level, 10 %of cross sectional area7.1 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"88.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"244.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: NO, Start267.5 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: NO, Finish267.5 ft. DAGS - Deposits Attached Grease, 30 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start287.7 ft. MSA - Survey Abandoned - CAMERA BLKD BY GREASE 30%287.7 ft. DAGS - Deposits Attached Grease, 30 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (2)

  • Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: NO, Start

    244.5 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: NO, Start

  • Deposits Attached Grease, 30 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES, Start

    267.5 ft. - Deposits Attached Grease, 30 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
267.5DAGS
287.7MSACAMERA BLKD BY GREASE 30%
0MWM
244.5DAGS
88.5TF
287.7DAGS
7.1TFA
0AMH08 0169
0MWL
267.5DAGS

Properties (9)

additional_info
SC411962
custom_field_three
GREASE
custom_field_two
5
customer
1
datetime
2020-09-25T02:32:09-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP
year_laid
37424