Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 19, 2020, 11:32 AM
  • 16 0049_16 0048_10192020_044816.mp4

Date
10/19/2020
W/O
849888
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00639
PipeID
P13062
Time
4:32 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8127
Sewer Name
ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_849888_TV16113_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0049
Downstream MH
16 0048
Dir. of Survey
Downstream
Length Surveyed
354.7 ft.
Total Length
354.7 ft.
Structural Index
3
Structural Quick
3M2M
Structural Rating
352
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
492
Pipe schematic from manhole 16 0049 to 16 0048
MH: 16 0049MH: 16 0048downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 00490 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - ROACHES @ MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CL - Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start352 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish354 ft. MGO - General Observation - ROACHES @ MH354.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish354.7 ft. AMH - Downstream Manhole, Survey Ends - 16 0048

Observation photos (2)

  • Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWL
3.1CM
0AMH16 0049
0MWM
354.7CM
2DAGS
354MGOROACHES @ MH
2CL
352SSS
2SSS
0MGOROACHES @ MH
354.7AMH16 0048
352DAGS

Properties (7)

additional_info
6301019200075A1
custom_field_three
MULTIPLE CRACKS/SPALLING
custom_field_two
3
customer
1
datetime
2020-10-19T04:32:58-07:00
documentation
PROPIPE
is_lateral_inspection
false