Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 19, 2020, 10:04 AM
  • 16 0047_16 0046_10192020_031540.mp4

Date
10/19/2020
W/O
849888
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00639
PipeID
P13060
Time
3:04 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8127
Sewer Name
ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_849888_TV16113_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0046
Downstream MH
16 0047
Dir. of Survey
Upstream
Length Surveyed
338.3 ft.
Total Length
338.3 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
332
O&M Index
2
O&M Quick
2L00
O&M Rating
134
Overall Index
2
Overall Quick
Overall Rating
466
Pipe schematic from manhole 16 0046 to 16 0047
MH: 16 0046MH: 16 0047upstream0 ft. AMH - Upstream Manhole, Survey Ends - 16 00470 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.3 ft. MGO - General Observation - ROACHES @ MH2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start336.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start336.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start338.3 ft. MWM - Water Mark, 10 %of cross sectional area338.3 ft. MWL - Water Level, 5 %of cross sectional area338.3 ft. AMH - Downstream Manhole, Survey Begins - 16 0046

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
336DAGS
336SSS
2SSS
0MWM
338.3AMH16 0047
0MWL
338MGOROACHES @ MH
2CM
2DAGS
338.3CM
0AMH16 0046

Properties (7)

additional_info
6301019200075A1
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2020-10-19T03:04:02-07:00
documentation
PROPIPE
is_lateral_inspection
false