Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 19, 2020, 10:54 AM
  • 16 0043_16 0042_10192020_040522.mp4

Date
10/19/2020
W/O
849888
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00639
PipeID
P13056
Time
3:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8127
Sewer Name
ALLEN AVENUE TRUNK, SECTS 1,2,&4
City
SAN GABRIEL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_849888_TV16113_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Width
16 in.
Upstream MH
16 0043
Downstream MH
16 0042
Dir. of Survey
Downstream
Length Surveyed
330.3 ft.
Total Length
330.3 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
328
O&M Index
2
O&M Quick
2L00
O&M Rating
132
Overall Index
2
Overall Quick
Overall Rating
460
Pipe schematic from manhole 16 0043 to 16 0042
MH: 16 0043MH: 16 0042downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 16 00432 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"98.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN235.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN273.8 ft. MGO - General Observation - CONN CHIPPED @ 10 O'CLOCK273.8 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 4", 2"328 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish328 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330 ft. MGO - General Observation - ROACHES @ MH330.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.3 ft. AMH - Downstream Manhole, Survey Ends - 16 0042

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"

    11.3 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    98.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

    235.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 4", 2"

    273.8 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 4", 2"

Observations (16)

DistanceCodeObservation
330MGOROACHES @ MH
2DAGS
273.8MGOCONN CHIPPED @ 10 O'CLOCK
0MWL
2.2CM
235.4TBOPEN
330.3CM
0MWM
98.8TBOPEN
2SSS
328DAGS
11.3TBA
328SSS
330.3AMH16 0042
273.8TBI
0AMH16 0043

Properties (7)

additional_info
6301019200075A1
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-10-19T03:54:07-07:00
documentation
PROPIPE
is_lateral_inspection
false