- Date
- 10/23/2020
- W/O
- 849681
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00763
- PipeID
- P15522
- Time
- 8:53 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8135
- Sewer Name
- DISTRICT #21 OUTFALL TRUNK
- City
- Pomona
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- RFIR_WO_849681_TV21101_SEP2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 21 0325
- Downstream MH
- 21 0324
- Dir. of Survey
- Downstream
- Length Surveyed
- 61.6 ft.
- Total Length
- 61.6 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 21 0325 to 21 0324 Observation photos (2)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start