Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 16, 2020, 07:57 AM
  • A 1202_A 1201 _10162020_010242.mp4

Date
10/16/2020
W/O
849615
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00973
PipeID
P02850
Time
12:57 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8126
Sewer Name
JOINT OUTFALL A - UNIT 9
City
BELL GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_849615_TV02207_SEP2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
39 in.
Width
15 in.
Upstream MH
A 1201
Downstream MH
A 1202
Dir. of Survey
Upstream
Length Surveyed
2.2 ft.
Total Length
2.2 ft.
Structural Index
4
Structural Quick
5141
Structural Rating
12
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole A 1201 to A 1202
MH: A 1201MH: A 1202upstream0 ft. MSA - Survey Abandoned - CAM BLKD BY DEBRIS/SLUDGE0 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO0 ft. MB - Missing Brick, from 08 to 04 o'clock - MISSING TILES0.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO0.1 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - DEBRIS/SLUDGE2.2 ft. AMH - Downstream Manhole, Survey Begins - A 12012.2 ft. MWL - Water Level, 20 %of cross sectional area2.2 ft. MGO - Reversal Inspection2.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (4)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO - DEBRIS/SLUDGE

    2.1 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - DEBRIS/SLUDGE

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    2.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

  • Missing Brick, from 08 to 04 o'clock - MISSING TILES

    2.2 ft. - Missing Brick, from 08 to 04 o'clock - MISSING TILES

Observations (9)

DistanceCodeObservation
2.1SAP
2.1DSZDEBRIS/SLUDGE
2.2MSACAM BLKD BY DEBRIS/SLUDGE
2.2SRV
2.2MBMISSING TILES
0AMHA 1201
0MWL
0MGO
0MWM

Properties (6)

additional_info
6301015200075P3
custom_field_two
5
customer
1
datetime
2020-10-16T00:57:53-07:00
documentation
PROPIPE
is_lateral_inspection
false