Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2020, 09:01 AM
  • A 1204_A 1203 _10062020_022752.mp4

Date
10/06/2020
W/O
849615
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00973
PipeID
P02852
Time
2:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8113
Sewer Name
JOINT OUTFALL A - UNIT 9
City
BELL GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_849615_TV02207_SEP2020
Sewer Type
Gravity
Material
RCP-CTL
Shape
Circular
Height
39 in.
Width
15 in.
Upstream MH
A 1204
Downstream MH
A 1203
Dir. of Survey
Downstream
Length Surveyed
358 ft.
Total Length
358 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole A 1204 to A 1203
MH: A 1204MH: A 1203downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 12040 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 07 o'clock, , within 8 inches of joint: NO, Start - DEBRIS/SLUDGE2.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.3 ft. MGO - General Observation - MISSING TILES357.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish357.8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish358 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 07 o'clock, , within 8 inches of joint: NO, Finish358 ft. AMH - Downstream Manhole, Survey Ends - A 1203

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Other,  15 %of cross sectional area, at 07 o'clock,  , within 8 inches of joint: NO, Start - DEBRIS/SLUDGE

    2.1 ft. - Deposits Settled Other, 15 %of cross sectional area, at 07 o'clock, , within 8 inches of joint: NO, Start - DEBRIS/SLUDGE

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
358DSZ
357.6SAP
357.8SRV
0MWL
6.3MGOMISSING TILES
0AMHA 1204
2.1SAP
0MWM
2.1DSZDEBRIS/SLUDGE
0MGOCONNECTION AT MH 3 O'CLOCK
358AMHA 1203
0MGOCONNECTION AT MH 9 O'CLOCK
2.1SRV

Properties (7)

additional_info
6301005200066P1
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2020-10-06T02:01:39-07:00
documentation
PROPIPE
is_lateral_inspection
false